-- BAY TECHNICAL ASSOCIATES (BAYTECH) MIB -- Copyright (c) Bay Technical Associates 2003. -- $Id: rs2.mib,v 1.3 2004/03/01 11:11:08 devel Exp $ -- Title: BAYTECH MIB for RS2 devices -- ************************************************************************* -- ************************************************************************ -- Baytech-MIB { iso org(3) dod(6) internet(1) private(4) -- enterprises(1) baytech(4779) } -- Baytech-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, IpAddress, Gauge, TimeTicks FROM RFC1155-SMI DisplayString FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215; baytech OBJECT IDENTIFIER ::= { enterprises 4779 } resseries OBJECT IDENTIFIER ::= { baytech 4 } res2 OBJECT IDENTIFIER ::= { resseries 1 } res2p2 OBJECT IDENTIFIER ::= { resseries 2 } rs2 OBJECT IDENTIFIER ::= { resseries 3 } rs4 OBJECT IDENTIFIER ::= { resseries 4 } rs2system OBJECT IDENTIFIER ::= { rs2 1 } rs2serial OBJECT IDENTIFIER ::= { rs2 2 } rs2power OBJECT IDENTIFIER ::= { rs2 3 } -- the rs2 system information -- the rs2 serial information -- the rs2 RPC information rs2PowerCntrlNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of attached RPCs." ::= { rs2power 1 } rs2PowerCntrlTable OBJECT-TYPE SYNTAX SEQUENCE OF RS2PowerCntrlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of RPC information." ::= { rs2power 2 } rs2PowerCntrlEntry OBJECT-TYPE SYNTAX RS2PowerCntrlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table entry of RPC information." INDEX { rs2CntrlIndex } ::= { rs2PowerCntrlTable 1 } RS2PowerCntrlEntry ::= SEQUENCE { rs2CntrlIndex INTEGER, rs2CntrlState INTEGER, rs2CntrlModelName DisplayString, rs2CntrlName DisplayString, rs2CntrlFirmwareVersion DisplayString, rs2CntrlNumberOfOutlets INTEGER, rs2CntrlNumberOfCurrentSensors INTEGER, rs2CntrlNumberOfVoltageSensors INTEGER, rs2CntrlNumberOfPowerSensors INTEGER, rs2CntrlNumberOfTemperatureSensors INTEGER, rs2CntrlNumberOfCircuitBreakers INTEGER, rs2CntrlTotalCurrent INTEGER, rs2CntrlMaxTotalCurrent INTEGER, rs2CntrlTotalPower INTEGER } rs2CntrlIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index into the RPC information table." ::= { rs2PowerCntrlEntry 1 } rs2CntrlState OBJECT-TYPE SYNTAX INTEGER { highCritical(1), highWarning(2), lowWarning(3), lowCritical(4), normal(5), notPresent(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The overall state relative to the thresholds." ::= { rs2PowerCntrlEntry 2 } rs2CntrlModelName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The model name of this RPC." ::= { rs2PowerCntrlEntry 3 } rs2CntrlName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) ACCESS read-write STATUS mandatory DESCRIPTION "The name of this RPC." ::= { rs2PowerCntrlEntry 4 } rs2CntrlFirmwareVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The firmware version of this RPC." ::= { rs2PowerCntrlEntry 5 } rs2CntrlNumberOfOutlets OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of controllable outlets on this RPC." ::= { rs2PowerCntrlEntry 6 } rs2CntrlNumberOfCurrentSensors OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of current sensors installed in this RPC." ::= { rs2PowerCntrlEntry 7 } rs2CntrlNumberOfVoltageSensors OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of voltage sensors installed in this RPC." ::= { rs2PowerCntrlEntry 8 } rs2CntrlNumberOfPowerSensors OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of power calculations for this RPC." ::= { rs2PowerCntrlEntry 9 } rs2CntrlNumberOfTemperatureSensors OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of temperature sensors installed in this RPC." ::= { rs2PowerCntrlEntry 10 } rs2CntrlNumberOfCircuitBreakers OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of circuit breakers installed in this RPC." ::= { rs2PowerCntrlEntry 11 } rs2CntrlTotalCurrent OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The combined total current of all current sensors in this RPC." ::= { rs2PowerCntrlEntry 12 } rs2CntrlMaxTotalCurrent OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The combined total maximum detected current of all current sensors in this RPC." ::= { rs2PowerCntrlEntry 13 } rs2CntrlTotalPower OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The combined total power of all power sensors in this RPC." ::= { rs2PowerCntrlEntry 14 } rs2OutletTable OBJECT-TYPE SYNTAX SEQUENCE OF RS2OutletEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of controllable RPC outlets." ::= { rs2power 3 } rs2OutletEntry OBJECT-TYPE SYNTAX RS2OutletEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table entry of controllable RPC outlets." INDEX { rs2OutletRPCIndex, rs2OutletIndex } ::= { rs2OutletTable 1 } RS2OutletEntry ::= SEQUENCE { rs2OutletRPCIndex INTEGER, rs2OutletIndex INTEGER, rs2OutletState INTEGER, rs2OutletName DisplayString } rs2OutletRPCIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of the RPC." ::= { rs2OutletEntry 1 } rs2OutletIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of the outlet." ::= { rs2OutletEntry 2 } rs2OutletState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), reboot(2), lockon(3), lockoff(4), unlock(5), unknown(6) } ACCESS read-write STATUS mandatory DESCRIPTION "Getting this variable will return the state of the outlet; setting this variable will set the state of the outlet." ::= { rs2OutletEntry 3 } rs2OutletName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) ACCESS read-write STATUS mandatory DESCRIPTION "The name of the outlet." ::= { rs2OutletEntry 4 } rs2AllOutletsTable OBJECT-TYPE SYNTAX SEQUENCE OF RS2AllOutletsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table to control all RPC outlets." ::= { rs2power 4 } rs2AllOutletsEntry OBJECT-TYPE SYNTAX RS2AllOutletsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table entry to control all RPC outlets." INDEX { rs2AllOutletsRPCIndex } ::= { rs2AllOutletsTable 1 } RS2AllOutletsEntry ::= SEQUENCE { rs2AllOutletsRPCIndex INTEGER, rs2AllOutletsState INTEGER, rs2AllOutletsStatus DisplayString } rs2AllOutletsRPCIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of the RPC." ::= { rs2AllOutletsEntry 1 } rs2AllOutletsState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), reboot(2), none(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Turns all outlets on, off or reboot." ::= { rs2AllOutletsEntry 2 } rs2AllOutletsStatus OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Reports status of outlets in a comma delimitated string (0 = off; 1 = on; 2 = reboot; 3 = locked on; 4 = locked off)." ::= { rs2AllOutletsEntry 3 } rs2CurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF RS2CurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of current values." ::= { rs2power 5 } rs2CurrentEntry OBJECT-TYPE SYNTAX RS2CurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table entry of current values." INDEX { rs2CurrentRPCIndex, rs2CurrentIndex } ::= { rs2CurrentTable 1 } RS2CurrentEntry ::= SEQUENCE { rs2CurrentRPCIndex INTEGER, rs2CurrentIndex INTEGER, rs2CurrentValue INTEGER, rs2CurrentMaxValue INTEGER, rs2CurrentState INTEGER, rs2CurrentHighCriticl INTEGER, rs2CurrentHighWarning INTEGER, rs2CurrentLowWarning INTEGER, rs2CurrentLowCritical INTEGER, rs2CurrentRearm INTEGER } rs2CurrentRPCIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of the RPC." ::= { rs2CurrentEntry 1 } rs2CurrentIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of the current sensor." ::= { rs2CurrentEntry 2 } rs2CurrentValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The current reading for this RPC sensor." ::= { rs2CurrentEntry 3 } rs2CurrentMaxValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum detected current reading for this RPC sensor." ::= { rs2CurrentEntry 4 } rs2CurrentState OBJECT-TYPE SYNTAX INTEGER { highCritical(1), highWarning(2), lowWarning(3), lowCritical(4), normal(5), notPresent(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state relative to the thresholds." ::= { rs2CurrentEntry 5 } rs2CurrentHighCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The current high critical threshold." ::= { rs2CurrentEntry 6 } rs2CurrentHighWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The current high warning threshold." ::= { rs2CurrentEntry 7 } rs2CurrentLowWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The current low warning threshold." ::= { rs2CurrentEntry 8 } rs2CurrentLowCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The current low critical threshold." ::= { rs2CurrentEntry 9 } rs2CurrentRearm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The current rearm value." ::= { rs2CurrentEntry 10 } rs2VoltageTable OBJECT-TYPE SYNTAX SEQUENCE OF RS2VoltageEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of voltage values." ::= { rs2power 6 } rs2VoltageEntry OBJECT-TYPE SYNTAX RS2VoltageEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table entry of voltage values." INDEX { rs2VoltageRPCIndex, rs2VoltageIndex } ::= { rs2VoltageTable 1 } RS2VoltageEntry ::= SEQUENCE { rs2VoltageRPCIndex INTEGER, rs2VoltageIndex INTEGER, rs2VoltageValue INTEGER, rs2VoltageState INTEGER, rs2VoltageHighCritical INTEGER, rs2VoltageHighWarning INTEGER, rs2VoltageLowWarning INTEGER, rs2VoltageLowCritical INTEGER, rs2VoltageRearm INTEGER } rs2VoltageRPCIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of the RPC." ::= { rs2VoltageEntry 1 } rs2VoltageIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of the voltage sensor." ::= { rs2VoltageEntry 2 } rs2VoltageValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The voltage reading for this RPC sensor." ::= { rs2VoltageEntry 3 } rs2VoltageState OBJECT-TYPE SYNTAX INTEGER { highCritical(1), highWarning(2), lowWarning(3), lowCritical(4), normal(5), notPresent(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The voltage state relative to the thresholds." ::= { rs2VoltageEntry 4 } rs2VoltageHighCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The voltage high critical threshold." ::= { rs2VoltageEntry 5 } rs2VoltageHighWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The voltage high warning threshold." ::= { rs2VoltageEntry 6 } rs2VoltageLowWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The voltage low warning threshold." ::= { rs2VoltageEntry 7 } rs2VoltageLowCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The voltage low critical threshold." ::= { rs2VoltageEntry 8 } rs2VoltageRearm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The voltage rearm value." ::= { rs2VoltageEntry 9 } rs2PowerTable OBJECT-TYPE SYNTAX SEQUENCE OF RS2PowerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of power values." ::= { rs2power 7 } rs2PowerEntry OBJECT-TYPE SYNTAX RS2PowerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table entry of power values." INDEX { rs2PowerRPCIndex, rs2PowerIndex } ::= { rs2PowerTable 1 } RS2PowerEntry ::= SEQUENCE { rs2PowerRPCIndex INTEGER, rs2PowerIndex INTEGER, rs2PowerValue INTEGER, rs2PowerState INTEGER, rs2PowerHighCritical INTEGER, rs2PowerHighWarning INTEGER, rs2PowerLowWarning INTEGER, rs2PowerLowCritical INTEGER, rs2PowerRearm INTEGER } rs2PowerRPCIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of the RPC." ::= { rs2PowerEntry 1 } rs2PowerIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of the power sensor." ::= { rs2PowerEntry 2 } rs2PowerValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The power reading for this RPC sensor." ::= { rs2PowerEntry 3 } rs2PowerState OBJECT-TYPE SYNTAX INTEGER { highCritical(1), highWarning(2), lowWarning(3), lowCritical(4), normal(5), notPresent(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The power state relative to the thresholds." ::= { rs2PowerEntry 4 } rs2PowerHighCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The power high critical threshold." ::= { rs2PowerEntry 5 } rs2PowerHighWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The power high warning threshold." ::= { rs2PowerEntry 6 } rs2PowerLowWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The power low warning threshold." ::= { rs2PowerEntry 7 } rs2PowerLowCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The power low critical threshold." ::= { rs2PowerEntry 8 } rs2PowerRearm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The power rearm value." ::= { rs2PowerEntry 9 } rs2TemperatureTable OBJECT-TYPE SYNTAX SEQUENCE OF RS2TemperatureEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of temperature values." ::= { rs2power 8 } rs2TemperatureEntry OBJECT-TYPE SYNTAX RS2TemperatureEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table entry of temperature values." INDEX { rs2TemperatureRPCIndex, rs2TemperatureIndex } ::= { rs2TemperatureTable 1 } RS2TemperatureEntry ::= SEQUENCE { rs2TemperatureRPCIndex INTEGER, rs2TemperatureIndex INTEGER, rs2TemperatureValue INTEGER, rs2TemperatureState INTEGER, rs2TemperatureHighCritical INTEGER, rs2TemperatureHighWarning INTEGER, rs2TemperatureLowWarning INTEGER, rs2TemperatureLowCritical INTEGER, rs2TemperatureRearm INTEGER } rs2TemperatureRPCIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of the RPC." ::= { rs2TemperatureEntry 1 } rs2TemperatureIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of the temperature sensor." ::= { rs2TemperatureEntry 2 } rs2TemperatureValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The temperature reading for this RPC sensor." ::= { rs2TemperatureEntry 3 } rs2TemperatureState OBJECT-TYPE SYNTAX INTEGER { highCritical(1), highWarning(2), lowWarning(3), lowCritical(4), normal(5), notPresent(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The temperature state relative to the thresholds." ::= { rs2TemperatureEntry 4 } rs2TemperatureHighCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The temperature high critical threshold." ::= { rs2TemperatureEntry 5 } rs2TemperatureHighWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The temperature high warning threshold." ::= { rs2TemperatureEntry 6 } rs2TemperatureLowWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The temperature low warning threshold." ::= { rs2TemperatureEntry 7 } rs2TemperatureLowCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The temperature low critical threshold." ::= { rs2TemperatureEntry 8 } rs2TemperatureRearm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The temperature rearm value." ::= { rs2TemperatureEntry 9 } rs2BreakersTable OBJECT-TYPE SYNTAX SEQUENCE OF RS2BreakersEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of circuit breaker states." ::= { rs2power 9 } rs2BreakersEntry OBJECT-TYPE SYNTAX RS2BreakersEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table entry of circuit breaker states." INDEX { rs2BreakersRPCIndex, rs2BreakersIndex } ::= { rs2BreakersTable 1 } RS2BreakersEntry ::= SEQUENCE { rs2BreakersRPCIndex INTEGER, rs2BreakersIndex INTEGER, rs2BreakersState INTEGER } rs2BreakersRPCIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index number of the RPC." ::= { rs2BreakersEntry 1 } rs2BreakersIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index number of the circuit breaker." ::= { rs2BreakersEntry 2 } rs2BreakersState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), notPresent(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The circuit breaker state." ::= { rs2BreakersEntry 3 } -- traps rs2Port1PowerSensor1HighCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2PowerRPCIndex, rs2PowerIndex, rs2PowerValue, rs2PowerState } DESCRIPTION "Port 1, power sensor 1, is in the high critical state." ::= 501 rs2Port1PowerSensor1HighWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2PowerRPCIndex, rs2PowerIndex, rs2PowerValue, rs2PowerState } DESCRIPTION "Port 1, power sensor 1, is in the high warning state." ::= 502 rs2Port1PowerSensor1LowWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2PowerRPCIndex, rs2PowerIndex, rs2PowerValue, rs2PowerState } DESCRIPTION "Port 1, power sensor 1, is in the low warning state." ::= 503 rs2Port1PowerSensor1LowCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2PowerRPCIndex, rs2PowerIndex, rs2PowerValue, rs2PowerState } DESCRIPTION "Port 1, power sensor 1, is in the low critical state." ::= 504 rs2Port1PowerSensor1Normal TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2PowerRPCIndex, rs2PowerIndex, rs2PowerValue, rs2PowerState } DESCRIPTION "Port 1, power sensor 1, is in the normal state." ::= 505 rs2Port1VoltageSensor1HighCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2VoltageRPCIndex, rs2VoltageIndex, rs2VoltageValue, rs2VoltageState } DESCRIPTION "Port 1, voltage sensor 1, is in the high critical state." ::= 506 rs2Port1VoltageSensor1HighWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2VoltageRPCIndex, rs2VoltageIndex, rs2VoltageValue, rs2VoltageState } DESCRIPTION "Port 1, voltage sensor 1, is in the high warning state." ::= 507 rs2Port1VoltageSensor1LowWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2VoltageRPCIndex, rs2VoltageIndex, rs2VoltageValue, rs2VoltageState } DESCRIPTION "Port 1, voltage sensor 1, is in the low warning state." ::= 508 rs2Port1VoltageSensor1LowCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2VoltageRPCIndex, rs2VoltageIndex, rs2VoltageValue, rs2VoltageState } DESCRIPTION "Port 1, voltage sensor 1, is in the low critical state." ::= 509 rs2Port1VoltageSensor1Normal TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2VoltageRPCIndex, rs2VoltageIndex, rs2VoltageValue, rs2VoltageState } DESCRIPTION "Port 1, voltage sensor 1, is in the normal state." ::= 510 rs2Port1CurrentSensor1HighCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2CurrentRPCIndex, rs2CurrentIndex, rs2CurrentValue, rs2CurrentState } DESCRIPTION "Port 1, current sensor 1, is in the high critical state." ::= 511 rs2Port1CurrentSensor1HighWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2CurrentRPCIndex, rs2CurrentIndex, rs2CurrentValue, rs2CurrentState } DESCRIPTION "Port 1, current sensor 1, is in the high warning state." ::= 512 rs2Port1CurrentSensor1LowWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2CurrentRPCIndex, rs2CurrentIndex, rs2CurrentValue, rs2CurrentState } DESCRIPTION "Port 1, current sensor 1, is in the low warning state." ::= 513 rs2Port1CurrentSensor1LowCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2CurrentRPCIndex, rs2CurrentIndex, rs2CurrentValue, rs2CurrentState } DESCRIPTION "Port 1, current sensor 1, is in the low critical state." ::= 514 rs2Port1CurrentSensor1Normal TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2CurrentRPCIndex, rs2CurrentIndex, rs2CurrentValue, rs2CurrentState } DESCRIPTION "Port 1, current sensor 1, is in the normal state." ::= 515 rs2Port1TemperatureSensor1HighCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2TemperatureRPCIndex, rs2TemperatureIndex, rs2TemperatureValue, rs2TemperatureState } DESCRIPTION "Port 1, temperature sensor 1, is in the high critical state." ::= 516 rs2Port1TemperatureSensor1HighWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2TemperatureRPCIndex, rs2TemperatureIndex, rs2TemperatureValue, rs2TemperatureState } DESCRIPTION "Port 1, temperature sensor 1, is in the high warning state." ::= 517 rs2Port1TemperatureSensor1LowWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2TemperatureRPCIndex, rs2TemperatureIndex, rs2TemperatureValue, rs2TemperatureState } DESCRIPTION "Port 1, temperature sensor 1, is in the low warning state." ::= 518 rs2Port1TemperatureSensor1LowCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2TemperatureRPCIndex, rs2TemperatureIndex, rs2TemperatureValue, rs2TemperatureState } DESCRIPTION "Port 1, temperature sensor 1, is in the low critical state." ::= 519 rs2Port1TemperatureSensor1Normal TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2TemperatureRPCIndex, rs2TemperatureIndex, rs2TemperatureValue, rs2TemperatureState } DESCRIPTION "Port 1, temperature sensor 1, is in the normal state." ::= 520 rs2Port1PowerSensor2HighCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2PowerRPCIndex, rs2PowerIndex, rs2PowerValue, rs2PowerState } DESCRIPTION "Port 1, power sensor 2, is in the high critical state." ::= 521 rs2Port1PowerSensor2HighWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2PowerRPCIndex, rs2PowerIndex, rs2PowerValue, rs2PowerState } DESCRIPTION "Port 1, power sensor 2, is in the high warning state." ::= 522 rs2Port1PowerSensor2LowWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2PowerRPCIndex, rs2PowerIndex, rs2PowerValue, rs2PowerState } DESCRIPTION "Port 1, power sensor 2, is in the low warning state." ::= 523 rs2Port1PowerSensor2LowCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2PowerRPCIndex, rs2PowerIndex, rs2PowerValue, rs2PowerState } DESCRIPTION "Port 1, power sensor 2, is in the low critical state." ::= 524 rs2Port1PowerSensor2Normal TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2PowerRPCIndex, rs2PowerIndex, rs2PowerValue, rs2PowerState } DESCRIPTION "Port 1, power sensor 2, is in the normal state." ::= 525 rs2Port1VoltageSensor2HighCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2VoltageRPCIndex, rs2VoltageIndex, rs2VoltageValue, rs2VoltageState } DESCRIPTION "Port 1, voltage sensor 2, is in the high critical state." ::= 526 rs2Port1VoltageSensor2HighWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2VoltageRPCIndex, rs2VoltageIndex, rs2VoltageValue, rs2VoltageState } DESCRIPTION "Port 1, voltage sensor 2, is in the high warning state." ::= 527 rs2Port1VoltageSensor2LowWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2VoltageRPCIndex, rs2VoltageIndex, rs2VoltageValue, rs2VoltageState } DESCRIPTION "Port 1, voltage sensor 2, is in the low warning state." ::= 528 rs2Port1VoltageSensor2LowCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2VoltageRPCIndex, rs2VoltageIndex, rs2VoltageValue, rs2VoltageState } DESCRIPTION "Port 1, voltage sensor 2, is in the low critical state." ::= 529 rs2Port1VoltageSensor2Normal TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2VoltageRPCIndex, rs2VoltageIndex, rs2VoltageValue, rs2VoltageState } DESCRIPTION "Port 1, voltage sensor 2, is in the normal state." ::= 530 rs2Port1CurrentSensor2HighCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2CurrentRPCIndex, rs2CurrentIndex, rs2CurrentValue, rs2CurrentState } DESCRIPTION "Port 1, current sensor 2, is in the high critical state." ::= 531 rs2Port1CurrentSensor2HighWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2CurrentRPCIndex, rs2CurrentIndex, rs2CurrentValue, rs2CurrentState } DESCRIPTION "Port 1, current sensor 2, is in the high warning state." ::= 532 rs2Port1CurrentSensor2LowWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2CurrentRPCIndex, rs2CurrentIndex, rs2CurrentValue, rs2CurrentState } DESCRIPTION "Port 1, current sensor 2, is in the low warning state." ::= 533 rs2Port1CurrentSensor2LowCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2CurrentRPCIndex, rs2CurrentIndex, rs2CurrentValue, rs2CurrentState } DESCRIPTION "Port 1, current sensor 2, is in the low critical state." ::= 534 rs2Port1CurrentSensor2Normal TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2CurrentRPCIndex, rs2CurrentIndex, rs2CurrentValue, rs2CurrentState } DESCRIPTION "Port 1, current sensor 2, is in the normal state." ::= 535 rs2Port1TemperatureSensor2HighCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2TemperatureRPCIndex, rs2TemperatureIndex, rs2TemperatureValue, rs2TemperatureState } DESCRIPTION "Port 1, temperature sensor 2, is in the high critical state." ::= 536 rs2Port1TemperatureSensor2HighWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2TemperatureRPCIndex, rs2TemperatureIndex, rs2TemperatureValue, rs2TemperatureState } DESCRIPTION "Port 1, temperature sensor 2, is in the high warning state." ::= 537 rs2Port1TemperatureSensor2LowWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2TemperatureRPCIndex, rs2TemperatureIndex, rs2TemperatureValue, rs2TemperatureState } DESCRIPTION "Port 1, temperature sensor 2, is in the low warning state." ::= 538 rs2Port1TemperatureSensor2LowCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2TemperatureRPCIndex, rs2TemperatureIndex, rs2TemperatureValue, rs2TemperatureState } DESCRIPTION "Port 1, temperature sensor 2, is in the low critical state." ::= 539 rs2Port1TemperatureSensor2Normal TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2TemperatureRPCIndex, rs2TemperatureIndex, rs2TemperatureValue, rs2TemperatureState } DESCRIPTION "Port 1, temperature sensor 2, is in the normal state." ::= 540 rs2Port1PowerSensor3HighCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2PowerRPCIndex, rs2PowerIndex, rs2PowerValue, rs2PowerState } DESCRIPTION "Port 1, power sensor 3, is in the high critical state." ::= 541 rs2Port1PowerSensor3HighWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2PowerRPCIndex, rs2PowerIndex, rs2PowerValue, rs2PowerState } DESCRIPTION "Port 1, power sensor 3, is in the high warning state." ::= 542 rs2Port1PowerSensor3LowWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2PowerRPCIndex, rs2PowerIndex, rs2PowerValue, rs2PowerState } DESCRIPTION "Port 1, power sensor 3, is in the low warning state." ::= 543 rs2Port1PowerSensor3LowCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2PowerRPCIndex, rs2PowerIndex, rs2PowerValue, rs2PowerState } DESCRIPTION "Port 1, power sensor 3, is in the low critical state." ::= 544 rs2Port1PowerSensor3Normal TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2PowerRPCIndex, rs2PowerIndex, rs2PowerValue, rs2PowerState } DESCRIPTION "Port 1, power sensor 3, is in the normal state." ::= 545 rs2Port1VoltageSensor3HighCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2VoltageRPCIndex, rs2VoltageIndex, rs2VoltageValue, rs2VoltageState } DESCRIPTION "Port 1, voltage sensor 3, is in the high critical state." ::= 546 rs2Port1VoltageSensor3HighWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2VoltageRPCIndex, rs2VoltageIndex, rs2VoltageValue, rs2VoltageState } DESCRIPTION "Port 1, voltage sensor 3, is in the high warning state." ::= 547 rs2Port1VoltageSensor3LowWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2VoltageRPCIndex, rs2VoltageIndex, rs2VoltageValue, rs2VoltageState } DESCRIPTION "Port 1, voltage sensor 3, is in the low warning state." ::= 548 rs2Port1VoltageSensor3LowCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2VoltageRPCIndex, rs2VoltageIndex, rs2VoltageValue, rs2VoltageState } DESCRIPTION "Port 1, voltage sensor 3, is in the low critical state." ::= 549 rs2Port1VoltageSensor3Normal TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2VoltageRPCIndex, rs2VoltageIndex, rs2VoltageValue, rs2VoltageState } DESCRIPTION "Port 1, voltage sensor 3, is in the normal state." ::= 550 rs2Port1CurrentSensor3HighCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2CurrentRPCIndex, rs2CurrentIndex, rs2CurrentValue, rs2CurrentState } DESCRIPTION "Port 1, current sensor 3, is in the high critical state." ::= 551 rs2Port1CurrentSensor3HighWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2CurrentRPCIndex, rs2CurrentIndex, rs2CurrentValue, rs2CurrentState } DESCRIPTION "Port 1, current sensor 3, is in the high warning state." ::= 552 rs2Port1CurrentSensor3LowWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2CurrentRPCIndex, rs2CurrentIndex, rs2CurrentValue, rs2CurrentState } DESCRIPTION "Port 1, current sensor 3, is in the low warning state." ::= 553 rs2Port1CurrentSensor3LowCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2CurrentRPCIndex, rs2CurrentIndex, rs2CurrentValue, rs2CurrentState } DESCRIPTION "Port 1, current sensor 3, is in the low critical state." ::= 554 rs2Port1CurrentSensor3Normal TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2CurrentRPCIndex, rs2CurrentIndex, rs2CurrentValue, rs2CurrentState } DESCRIPTION "Port 1, current sensor 3, is in the normal state." ::= 555 rs2Port1TemperatureSensor3HighCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2TemperatureRPCIndex, rs2TemperatureIndex, rs2TemperatureValue, rs2TemperatureState } DESCRIPTION "Port 1, temperature sensor 3, is in the high critical state." ::= 556 rs2Port1TemperatureSensor3HighWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2TemperatureRPCIndex, rs2TemperatureIndex, rs2TemperatureValue, rs2TemperatureState } DESCRIPTION "Port 1, temperature sensor 3, is in the high warning state." ::= 557 rs2Port1TemperatureSensor3LowWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2TemperatureRPCIndex, rs2TemperatureIndex, rs2TemperatureValue, rs2TemperatureState } DESCRIPTION "Port 1, temperature sensor 3, is in the low warning state." ::= 558 rs2Port1TemperatureSensor3LowCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2TemperatureRPCIndex, rs2TemperatureIndex, rs2TemperatureValue, rs2TemperatureState } DESCRIPTION "Port 1, temperature sensor 3, is in the low critical state." ::= 559 rs2Port1TemperatureSensor3Normal TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2TemperatureRPCIndex, rs2TemperatureIndex, rs2TemperatureValue, rs2TemperatureState } DESCRIPTION "Port 1, temperature sensor 3, is in the normal state." ::= 560 rs2Port2PowerSensor1HighCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2PowerRPCIndex, rs2PowerIndex, rs2PowerValue, rs2PowerState } DESCRIPTION "Port 2, power sensor 1, is in the high critical state." ::= 561 rs2Port2PowerSensor1HighWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2PowerRPCIndex, rs2PowerIndex, rs2PowerValue, rs2PowerState } DESCRIPTION "Port 2, power sensor 1, is in the high warning state." ::= 562 rs2Port2PowerSensor1LowWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2PowerRPCIndex, rs2PowerIndex, rs2PowerValue, rs2PowerState } DESCRIPTION "Port 2, power sensor 1, is in the low warning state." ::= 563 rs2Port2PowerSensor1LowCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2PowerRPCIndex, rs2PowerIndex, rs2PowerValue, rs2PowerState } DESCRIPTION "Port 2, power sensor 1, is in the low critical state." ::= 564 rs2Port2PowerSensor1Normal TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2PowerRPCIndex, rs2PowerIndex, rs2PowerValue, rs2PowerState } DESCRIPTION "Port 2, power sensor 1, is in the normal state." ::= 565 rs2Port2VoltageSensor1HighCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2VoltageRPCIndex, rs2VoltageIndex, rs2VoltageValue, rs2VoltageState } DESCRIPTION "Port 2, voltage sensor 1, is in the high critical state." ::= 566 rs2Port2VoltageSensor1HighWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2VoltageRPCIndex, rs2VoltageIndex, rs2VoltageValue, rs2VoltageState } DESCRIPTION "Port 2, voltage sensor 1, is in the high warning state." ::= 567 rs2Port2VoltageSensor1LowWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2VoltageRPCIndex, rs2VoltageIndex, rs2VoltageValue, rs2VoltageState } DESCRIPTION "Port 2, voltage sensor 1, is in the low warning state." ::= 568 rs2Port2VoltageSensor1LowCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2VoltageRPCIndex, rs2VoltageIndex, rs2VoltageValue, rs2VoltageState } DESCRIPTION "Port 2, voltage sensor 1, is in the low critical state." ::= 569 rs2Port2VoltageSensor1Normal TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2VoltageRPCIndex, rs2VoltageIndex, rs2VoltageValue, rs2VoltageState } DESCRIPTION "Port 2, voltage sensor 1, is in the normal state." ::= 570 rs2Port2CurrentSensor1HighCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2CurrentRPCIndex, rs2CurrentIndex, rs2CurrentValue, rs2CurrentState } DESCRIPTION "Port 2, current sensor 1, is in the high critical state." ::= 571 rs2Port2CurrentSensor1HighWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2CurrentRPCIndex, rs2CurrentIndex, rs2CurrentValue, rs2CurrentState } DESCRIPTION "Port 2, current sensor 1, is in the high warning state." ::= 572 rs2Port2CurrentSensor1LowWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2CurrentRPCIndex, rs2CurrentIndex, rs2CurrentValue, rs2CurrentState } DESCRIPTION "Port 2, current sensor 1, is in the low warning state." ::= 573 rs2Port2CurrentSensor1LowCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2CurrentRPCIndex, rs2CurrentIndex, rs2CurrentValue, rs2CurrentState } DESCRIPTION "Port 2, current sensor 1, is in the low critical state." ::= 574 rs2Port2CurrentSensor1Normal TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2CurrentRPCIndex, rs2CurrentIndex, rs2CurrentValue, rs2CurrentState } DESCRIPTION "Port 2, current sensor 1, is in the normal state." ::= 575 rs2Port2TemperatureSensor1HighCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2TemperatureRPCIndex, rs2TemperatureIndex, rs2TemperatureValue, rs2TemperatureState } DESCRIPTION "Port 2, temperature sensor 1, is in the high critical state." ::= 576 rs2Port2TemperatureSensor1HighWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2TemperatureRPCIndex, rs2TemperatureIndex, rs2TemperatureValue, rs2TemperatureState } DESCRIPTION "Port 2, temperature sensor 1, is in the high warning state." ::= 577 rs2Port2TemperatureSensor1LowWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2TemperatureRPCIndex, rs2TemperatureIndex, rs2TemperatureValue, rs2TemperatureState } DESCRIPTION "Port 2, temperature sensor 1, is in the low warning state." ::= 578 rs2Port2TemperatureSensor1LowCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2TemperatureRPCIndex, rs2TemperatureIndex, rs2TemperatureValue, rs2TemperatureState } DESCRIPTION "Port 2, temperature sensor 1, is in the low critical state." ::= 579 rs2Port2TemperatureSensor1Normal TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2TemperatureRPCIndex, rs2TemperatureIndex, rs2TemperatureValue, rs2TemperatureState } DESCRIPTION "Port 2, temperature sensor 1, is in the normal state." ::= 580 rs2Port2PowerSensor2HighCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2PowerRPCIndex, rs2PowerIndex, rs2PowerValue, rs2PowerState } DESCRIPTION "Port 2, power sensor 2, is in the high critical state." ::= 581 rs2Port2PowerSensor2HighWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2PowerRPCIndex, rs2PowerIndex, rs2PowerValue, rs2PowerState } DESCRIPTION "Port 2, power sensor 2, is in the high warning state." ::= 582 rs2Port2PowerSensor2LowWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2PowerRPCIndex, rs2PowerIndex, rs2PowerValue, rs2PowerState } DESCRIPTION "Port 2, power sensor 2, is in the low warning state." ::= 583 rs2Port2PowerSensor2LowCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2PowerRPCIndex, rs2PowerIndex, rs2PowerValue, rs2PowerState } DESCRIPTION "Port 2, power sensor 2, is in the low critical state." ::= 584 rs2Port2PowerSensor2Normal TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2PowerRPCIndex, rs2PowerIndex, rs2PowerValue, rs2PowerState } DESCRIPTION "Port 2, power sensor 2, is in the normal state." ::= 585 rs2Port2VoltageSensor2HighCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2VoltageRPCIndex, rs2VoltageIndex, rs2VoltageValue, rs2VoltageState } DESCRIPTION "Port 2, voltage sensor 2, is in the high critical state." ::= 586 rs2Port2VoltageSensor2HighWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2VoltageRPCIndex, rs2VoltageIndex, rs2VoltageValue, rs2VoltageState } DESCRIPTION "Port 2, voltage sensor 2, is in the high warning state." ::= 587 rs2Port2VoltageSensor2LowWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2VoltageRPCIndex, rs2VoltageIndex, rs2VoltageValue, rs2VoltageState } DESCRIPTION "Port 2, voltage sensor 2, is in the low warning state." ::= 588 rs2Port2VoltageSensor2LowCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2VoltageRPCIndex, rs2VoltageIndex, rs2VoltageValue, rs2VoltageState } DESCRIPTION "Port 2, voltage sensor 2, is in the low critical state." ::= 589 rs2Port2VoltageSensor2Normal TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2VoltageRPCIndex, rs2VoltageIndex, rs2VoltageValue, rs2VoltageState } DESCRIPTION "Port 2, voltage sensor 2, is in the normal state." ::= 590 rs2Port2CurrentSensor2HighCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2CurrentRPCIndex, rs2CurrentIndex, rs2CurrentValue, rs2CurrentState } DESCRIPTION "Port 2, current sensor 2, is in the high critical state." ::= 591 rs2Port2CurrentSensor2HighWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2CurrentRPCIndex, rs2CurrentIndex, rs2CurrentValue, rs2CurrentState } DESCRIPTION "Port 2, current sensor 2, is in the high warning state." ::= 592 rs2Port2CurrentSensor2LowWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2CurrentRPCIndex, rs2CurrentIndex, rs2CurrentValue, rs2CurrentState } DESCRIPTION "Port 2, current sensor 2, is in the low warning state." ::= 593 rs2Port2CurrentSensor2LowCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2CurrentRPCIndex, rs2CurrentIndex, rs2CurrentValue, rs2CurrentState } DESCRIPTION "Port 2, current sensor 2, is in the low critical state." ::= 594 rs2Port2CurrentSensor2Normal TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2CurrentRPCIndex, rs2CurrentIndex, rs2CurrentValue, rs2CurrentState } DESCRIPTION "Port 2, current sensor 2, is in the normal state." ::= 595 rs2Port2TemperatureSensor2HighCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2TemperatureRPCIndex, rs2TemperatureIndex, rs2TemperatureValue, rs2TemperatureState } DESCRIPTION "Port 2, temperature sensor 2, is in the high critical state." ::= 596 rs2Port2TemperatureSensor2HighWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2TemperatureRPCIndex, rs2TemperatureIndex, rs2TemperatureValue, rs2TemperatureState } DESCRIPTION "Port 2, temperature sensor 2, is in the high warning state." ::= 597 rs2Port2TemperatureSensor2LowWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2TemperatureRPCIndex, rs2TemperatureIndex, rs2TemperatureValue, rs2TemperatureState } DESCRIPTION "Port 2, temperature sensor 2, is in the low warning state." ::= 598 rs2Port2TemperatureSensor2LowCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2TemperatureRPCIndex, rs2TemperatureIndex, rs2TemperatureValue, rs2TemperatureState } DESCRIPTION "Port 2, temperature sensor 2, is in the low critical state." ::= 599 rs2Port2TemperatureSensor2Normal TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2TemperatureRPCIndex, rs2TemperatureIndex, rs2TemperatureValue, rs2TemperatureState } DESCRIPTION "Port 2, temperature sensor 2, is in the normal state." ::= 600 rs2Port2PowerSensor3HighCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2PowerRPCIndex, rs2PowerIndex, rs2PowerValue, rs2PowerState } DESCRIPTION "Port 2, power sensor 3, is in the high critical state." ::= 601 rs2Port2PowerSensor3HighWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2PowerRPCIndex, rs2PowerIndex, rs2PowerValue, rs2PowerState } DESCRIPTION "Port 2, power sensor 3, is in the high warning state." ::= 602 rs2Port2PowerSensor3LowWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2PowerRPCIndex, rs2PowerIndex, rs2PowerValue, rs2PowerState } DESCRIPTION "Port 2, power sensor 3, is in the low warning state." ::= 603 rs2Port2PowerSensor3LowCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2PowerRPCIndex, rs2PowerIndex, rs2PowerValue, rs2PowerState } DESCRIPTION "Port 2, power sensor 3, is in the low critical state." ::= 604 rs2Port2PowerSensor3Normal TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2PowerRPCIndex, rs2PowerIndex, rs2PowerValue, rs2PowerState } DESCRIPTION "Port 2, power sensor 3, is in the normal state." ::= 605 rs2Port2VoltageSensor3HighCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2VoltageRPCIndex, rs2VoltageIndex, rs2VoltageValue, rs2VoltageState } DESCRIPTION "Port 2, voltage sensor 3, is in the high critical state." ::= 606 rs2Port2VoltageSensor3HighWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2VoltageRPCIndex, rs2VoltageIndex, rs2VoltageValue, rs2VoltageState } DESCRIPTION "Port 2, voltage sensor 3, is in the high warning state." ::= 607 rs2Port2VoltageSensor3LowWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2VoltageRPCIndex, rs2VoltageIndex, rs2VoltageValue, rs2VoltageState } DESCRIPTION "Port 2, voltage sensor 3, is in the low warning state." ::= 608 rs2Port2VoltageSensor3LowCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2VoltageRPCIndex, rs2VoltageIndex, rs2VoltageValue, rs2VoltageState } DESCRIPTION "Port 2, voltage sensor 3, is in the low critical state." ::= 609 rs2Port2VoltageSensor3Normal TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2VoltageRPCIndex, rs2VoltageIndex, rs2VoltageValue, rs2VoltageState } DESCRIPTION "Port 2, voltage sensor 3, is in the normal state." ::= 610 rs2Port2CurrentSensor3HighCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2CurrentRPCIndex, rs2CurrentIndex, rs2CurrentValue, rs2CurrentState } DESCRIPTION "Port 2, current sensor 3, is in the high critical state." ::= 611 rs2Port2CurrentSensor3HighWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2CurrentRPCIndex, rs2CurrentIndex, rs2CurrentValue, rs2CurrentState } DESCRIPTION "Port 2, current sensor 3, is in the high warning state." ::= 612 rs2Port2CurrentSensor3LowWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2CurrentRPCIndex, rs2CurrentIndex, rs2CurrentValue, rs2CurrentState } DESCRIPTION "Port 2, current sensor 3, is in the low warning state." ::= 613 rs2Port2CurrentSensor3LowCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2CurrentRPCIndex, rs2CurrentIndex, rs2CurrentValue, rs2CurrentState } DESCRIPTION "Port 2, current sensor 3, is in the low critical state." ::= 614 rs2Port2CurrentSensor3Normal TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2CurrentRPCIndex, rs2CurrentIndex, rs2CurrentValue, rs2CurrentState } DESCRIPTION "Port 2, current sensor 3, is in the normal state." ::= 615 rs2Port2TemperatureSensor3HighCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2TemperatureRPCIndex, rs2TemperatureIndex, rs2TemperatureValue, rs2TemperatureState } DESCRIPTION "Port 2, temperature sensor 3, is in the high critical state." ::= 616 rs2Port2TemperatureSensor3HighWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2TemperatureRPCIndex, rs2TemperatureIndex, rs2TemperatureValue, rs2TemperatureState } DESCRIPTION "Port 2, temperature sensor 3, is in the high warning state." ::= 617 rs2Port2TemperatureSensor3LowWarning TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2TemperatureRPCIndex, rs2TemperatureIndex, rs2TemperatureValue, rs2TemperatureState } DESCRIPTION "Port 2, temperature sensor 3, is in the low warning state." ::= 618 rs2Port2TemperatureSensor3LowCritical TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2TemperatureRPCIndex, rs2TemperatureIndex, rs2TemperatureValue, rs2TemperatureState } DESCRIPTION "Port 2, temperature sensor 3, is in the low critical state." ::= 619 rs2Port2TemperatureSensor3Normal TRAP-TYPE ENTERPRISE rs2 VARIABLES { sysDescr, rs2TemperatureRPCIndex, rs2TemperatureIndex, rs2TemperatureValue, rs2TemperatureState } DESCRIPTION "Port 2, temperature sensor 3, is in the normal state." ::= 620 END